Table 6-8 Error Codes (continued)
Code
Error
1114
Controller requires non-failed
physical drives to set license
keys
1111
Invalid license key
1112
Controller has maximum number of
license keys
1110
License key is not a controller
feature license key
2850
Controller does not support Raid
Array ID
2851
Invalid Raid Array ID
1091
Controller does not support SSP
2855
Controller does not support
Logical Drive SSP states. Use
'SSPState' Controller command to
set the Controller SSP state
2856
Controller does not support
Controller SSP state. Use
'LogicalDriveSSPState' Logical
Drive command to set SSP states
for each Logical Drive
2853
Cannot change SSP settings
2854
Invalid SSP Adapter ID
2852
Invalid SSP State
2858
Controller does not support
snapshot resource volume feature
2859
Invalid Resource Volume Owner
2860
Cannot change Resource Volume
Owner
2861
Controller does not support
redundancy settings
2864
Invalid Preferred Path Mode
2865
Invalid Preferred Path
2876
Invalid Physical Drive Count
2877
No Spares Available
66
Utilities Reference
Reason
The controller requires non-failed physical drives for license
keys.
The entered license key is not a valid license key.
The controller already has the maximum number of license
keys installed.
The entered license key is not a controller feature license key.
The controller does not support Raid Array ID.
The entered Raid Array ID is invalid. The Raid Array ID can
only consist of the following characters: a-z A-Z 0-9 ! @ # * (
) , - _ + : . / [space]. It cannot end with a space character or
exceed the maximum number of characters allowed by the
controller.
The controller does not support SSP.
The Controller does not support Logical Drive SSP states.
Use SSPState controller command to set the Controller SSP
state.
Controller does not support Controller SSP state. Use
LogicalDriveSSPState logical drive command to set SSP
states for each Logical Drive.
The SSP settings cannot be changed for the controller or
logical drive.
The adapter ID is not a valid adapter ID that was detected
by the controller.
The requested SSP State is not a valid SSP state.
The controller does not support the snapshot resource volume
feature.
The specified Resource Volume Owner is not valid. The
Resource Volume Owner should be a valid existing logical
drive ID.
The Resource Volume owner cannot be changed if it is a
configured logical drive.
The controller is not redundant or does not support
redundancy settings.
The preferred path mode is not a valid preferred path mode
or the controller is not available.
The preferred path specified is not a valid chassis-slot for an
available active controller or the controller is not available.
Invalid Physical Drive count. A possible reason is that more
disks were requested than available of the current DriveType.
No suitable Spares available.