87
Users Manual
Function
Capacitance
Diode Test
Function
mA †
(45 Hz to 2 kHz)
mA
*** With film capacitor or better, using Relative mode to zero residual.
†† 10A continuous, 20A for 30 seconds maximum.
38
Specifications (cont)
Range
Resolution
5.00 nF
0.01 nF
0.0500 F
0.0001 F
0.500 F
0.001 F
5.00 F
0.01 F
3.000V
0.001V
Range
Resolution
40.00 mA
0.01 mA
400.0 mA
0.1 mA
4000 mA
1 mA
10.00A††
0.01A
40.00 mA
0.01 mA
400.0 mA
0.1 mA
4000 mA
1 mA
10.00 A††
0.01A
See page 34 for a complete explanation of this notation.
Accuracy***
(1% + 3)
(1% + 3)
(1% + 3)
(1.9% + 3)
(2% + 1)
Accuracy*
Burden Voltage (typical)
(1.0% + 2)
(1.0% + 2)
(1.0% + 2)
(1.0% + 2)
(0.2% + 2)
(0.2% + 2)
(0.2% + 2)
(0.2% + 2)
1.8 mV/mA
1.8 mV/mA
0.03 V/A
0.03 V/A
1.8 mV/mA
1.8 mV/mA
0.03 V/A
0.03 V/A