GE NX-1308E - Caddx 8 Zone LED Keypad Installation And Startup Manual page 43

Networx series
Table of Contents

Advertisement

LOC
PG
L
Segment #3 (Circle numbers to program)
37
23
1
Box Tamper report enabled.
2
AC Fail report enabled.
3
Low Battery report enabled.
4
Auxiliary power over current report enabled.
5
Siren supervision report enabled.
6
Telephone Line Cut report enabled.
7
Ground Fault Detection report enabled.
8
Expander trouble report enabled.
Segment #4 (Circle numbers to program)
1
Failure To Communicate report enabled.
2
Log Full report enabled.
3
Autotest report enabled.
4
Start and End Programming report enabled.
5
End Download report enabled.
6
Sensor Low Battery report enabled.
7
Sensor Missing report enabled.
Reserved.
8
Segment #5 (Circle numbers to program)
1
Lost Clock service LED enable.
2
Zone Doubling enable.
3
Disable on-board eight zones.
4
Enables two trips on the same cross-zone to activate the alarm.
5
Disables bypass reports for force armed zones
6
Reserved.
7
Clock uses internal crystal.
Disable Temporal Siren on Fire (Do not disable on UL listed systems)
8
L
38
23
SWINGER SHUTDOWN COUNT
L
39
23
KEYPAD SOUNDER CONTROL
Segment #1 (Circle numbers to program)
1
Keypad sounds for Telephone Line Cut when in the Armed state.
2
Keypad sounds for Telephone Line Cut when in the Disarmed state.
3
Keypad sounds upon AC Power Failure.
4
Keypad sounds upon Low Battery Detection.
5
Keypad sounds during Cross Zone Trip Time.
6
Keypad sounds for Tamper Alarm.
Reserved.
7
Keypad sounds for expander trouble (required for UL).
8
L
40
24
SYSTEM TIMERS
Segment #1 Dynamic Battery Test duration (0-255 minutes)
Segment #2 AC Failure report delay (0-255 minutes)
Segment #3 Power Up Delay (0-60 seconds)
Segment #4 Siren Time (1-254 minutes)
Segment #5 Telephone Line Cut delay (0-255 seconds)
Segment #6 Cross Zone Time (0-255 minutes)
Segment #7 Chime Time in 50 mS increments (0-255)
Segment #8 Dialer delay (15-255 seconds)
Segment #9 Fire Alarm Verification Time (120-255 sec.)
Segment #10 Listen-In Time (0-255 seconds)
NX-8 Control
DESCRIPTION
DEFAULT
DATA
1
0
5
60
8
0
5
3
30
0
0
_
_
_
_
_
_
_
_
_
_
_
43