Rebuild A Mirrored Array - TYAN TOMCAT I915 User Manual

Table of Contents

Advertisement

Tomcat i915 S5120
The boot sector maps the data partition on the disk drive. To delete an array without deleting
the data, press N. This action is sometimes part of a data recovery operation, under the
direction of Technical Support.
After deleting the array, create a new array using Auto Setup (1) or the Define Array (3) from
the Main Menu.

4.5.7 Rebuild a Mirrored Array

Use the Rebuild Array (5) Menu option to recover from an error in a mirrored (RAID 1) disk
array.
Note the Critical Status of the array shown above. If you observe this condition when booting
your system from the FastTrak BIOS, your array needs attention.
Follow these steps before using the Rebuild Array menu option:
1. Press Ctrl-F to enter FastBuild Main Menu.
2. Press 3 to select Define Array.
3. Press the arrow keys to highlight the failed array and press Enter to select it.
4. In the Array Definition menu, in the Drive Assignments field, identify the failed drive. In the
example above, the drive in Channel 2 has failed.
5. Press Esc twice to Exit the FastBuild Utility.
Chapter 4: SATA/RAID Setup (for SATA RAID model)
Drives MUST be replaced if they contain any physical errors, before
rebuilding the array.
http://www.tyan.com
Important
4-20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tomcat i915 s5120S5120

Table of Contents