OPERATING FIREPLACE
Continued
6. With control knob pressed in, push down
and release ignitor button. This will light
pilot. The pilot is attached to the front of
burner. If needed, keep pressing ignitor
button until pilot lights.
Note: If pilot does not stay lit, refer to
Troubleshooting, page 22. Also contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure.
7. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
Note: If pilot goes out, repeat steps 3
through 7. This fireplace has a safety in-
terlock system. Wait one (1) minute before
lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The main burner
should light. Set control knob to any heat
level between HI and LO.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
Pilot Burner
Ignitor
Electrode
Figure 26 - Pilot
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Fireplace
1. Turn control knob clockwise
OFF position.
2. Turn off all electric power to the appliance
if service is to be performed.
Shutting Off burner Only (pilot stays lit)
Turn control knob clockwise
LOT position.
111044-01J
Thermocouple
to the
to the PI-
www.desatech.com
THERMOSTAT
CONTROL OPERATION
The thermostatic control used on this fireplace
differs from standard thermostats. Standard
thermostats simply turn on and off the burner.
The thermostat used on this fireplace senses the
room temperature. The thermostat adjusts the
amount of gas flow to the burner. This increases
or decreases the burner flame height. At times
the heater will cycle back on when room tem-
perature drops below the set temperature.
The control knob can be set to any heat level
between HI and LO.
Note: The thermostat sensing bulb measures
the temperature of air near the fireplace
cabinet. This may not always agree with
room temperature (depending on housing
construction, installation location, room size,
open air temperatures, etc.). Frequent use of
your fireplace will let you determine your own
comfort levels.

MANUAL LIGHTING

PROCEDURE
1. Follow steps 1 through 5 under Lighting
Instructions, page 18.
2. With control knob pressed in, strike match.
Hold match to pilot until pilot lights.
3. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob. Now follow step 8 under
Lighting Instructions, column 1.