Desa CGCFTP, CGCFTN Owner's Operation And Installation Manual page 12

Vent-free compact fireplace
Table of Contents

Advertisement

INSTALLATION
Continued
MANTEL CLEARANCES FOR BUILT-
IN INSTALLATION
If placing mantel above built-in fireplace, you must
meet minimum clearance between mantel shelf and
top of fireplace opening.
NOTICE: Surface temperatures
of adjacent walls and mantels
become hot during operation.
Walls and mantels above the
firebox may become hot to
the touch. If installed properly,
these temperatures meet the
requirement of the national
product standard. Follow all
minimum clearances shown in
this manual.
NOTICE: If your installation does
not meet the minimum clear-
ances shown, you must do one
of the following:
• raise the mantel to an accept-
able height
• remove the mantel
Note: All vertical
Note:
measurements are
A ll vertical
from top of fireplace
measurements
opening to bottom
are from top of
of mantel shelf. All
fireplace
measurements are
opening to
in inches.
bottom of
mantel shelf. All
measurements
Side of
are in inches.
Firebox
Figure 11 - Minimum Mantel Clearances
for Built-In Installation
1
Mantel Shelf
10"
8"
6"
1
2
/
"
2
www.desatech.com
OPTIONAL MANTEL INSTALLATION
Refer to instructions provided with the mantel
for assembly and installation instructions. Refer
to instructions on page 4 for firebox assembly. If
a blower accessory is being used, it should be in-
stalled before securing your fireplace to the mantel
(see Installing Blower Accessory GA3450TA).
INSTALLING BLOWER ACCESSORY
GA3450TA
Removing Upper Louver Assembly
To install the blower accessory, you must first
remove the upper louver assembly.
1. Lift screen off heater.
2. Remove 4 screws from louver assembly (see
Figure 12). Save these screws.
3. Pull louver assembly straight out from the
cabinet. Be careful not to scratch the paint.
Set louver assembly and screws aside.
Figure 12 - Removing Upper Louver
Assembly
Removing Valve Cover Shield
1. Open bottom louver assembly by swinging
the assembly down (see Figure 13, page 13).
2. Using short Phillips screwdriver, remove the
screw under the center of the branch support.
Rotate valve cover shield clockwise and slide
out. IMPORTANT: Do not remove shoulder
screw on the left side of valve cover shield.
Slide the valve cover shield off of the shoulder
screw (see Figure 13, page 13).
Note: If you do not have a short Phillips
screwdriver, the screen, log set and branch
support must be removed so a longer screw-
driver may be used. See Connecting Equip-
ment Shutoff Valve to Heater Control, page
16, steps 1 and 2.
Blower Bracket
Mounting Holes
Upper
Louver
Screws
Assembly
111044-01J

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hdcftp, hdcftn, cgcftp, cgcftnHdcftpHdcftnCgcftpCgcftn

Table of Contents