Environment Monitoring - Cisco AS5400HPX Installation Manual

Universal gateway chassis
Hide thumbs Also See for AS5400HPX:
Table of Contents

Advertisement

Environment Monitoring

OIR events:
DFC State is DFC_S_OPERATIONAL
Slot 5:
DFC type is AS5400 Empty DFC
DFC is not powered
OIR events:
Slot 6:
Carrier Slot is Empty
Slot 7:
Carrier Slot is Empty

Environment Monitoring

The Cisco AS5400 contains temperature sensors to detect abnormal temperature conditions during
system operation. The three levels of sensor detection are as follows:
1.
2.
Note
3.
Cisco AS5400 Universal Gateway Chassis Installation Guide
4-4
Number of insertions = 0, Number of removals = 0
Number of insertions = 0, Number of removals = 0
When the operating temperature of the system exceeds 45° C, the system reaches a warning state. A
warning message appears on the console. When the operating temperature of the system drops below
45° C, another message is displayed on the console indicating a recovery. At this level of sensor
detection, there is no disruption in system operation.
When the operating temperature of the system continues to rise above 45° C and reaches a
temperature of 60° C, the system reaches a critical state.
Cisco IOS software busys out the DFCs in the chassis and shuts down the first DFC. If the operating
temperature continues to be critical after 10 minutes, Cisco IOS software shuts down another DFC.
DFC slot numbering starts from the system board and works up from left to right.
Slot 0 is reserved for the system board. The DFC slots are numbered sequentially
from 1 to 7.
This process is repeated at 10 minute intervals until the final DFC is shut down. The console displays
the slot number of the DFC and the type of DFC that was shut down.
If the operating temperature cools down to 45° C, Cisco IOS software powers on the first DFC,
repeating the process for each DFC at 10 minute intervals.
When the operating temperature of the system rises above 65° C, Cisco IOS software shuts down all
DFCs immediately.
Chapter 4
Troubleshooting