System Troubles - Honeywell 6272CV User Manual

Ademco 6272 series touchcenter keypads
Table of Contents

Advertisement

About the TouchCenter (cont'd)
ITEM
Arm Multi-
Press this button when you want to arm more than one partition. All
Partitions
partitions within the system can be armed at one time (if the user is so
authorized). Note: This option may not be shown for some single partition
systems.
MORE
Press this button for more Security, Lighting, and TouchCenter setup
CHOICES
features.

System Troubles

The "Arming" screen also displays an Icon(s) if a system trouble(s)
occurs. The system trouble Icon is displayed to the left of the Panic
button. If a trouble Icon is shown, contact your alarm company. The
following Icons may be shown as applicable to your system:
ICON
AC Loss – The system is not receiving AC power.
Bell Failure – The system bell or siren has a problem. Note: This Icon will be
displayed when interfacing with residential panels only.
Expander Failure – The system has a failure in an expansion module.
Low Battery – The system battery, that powers the system during an AC
power loss, is low.
LRR Supervision Failure – The Long Range Radio used to communicate with
the central station has a supervision failure
Max Attempts Exceeded – The system has exceeded the maximum attempts
to communicate with the Central Station.
Pager Failure – The system cannot communicate with an assigned pager.
Telco-1 Cut – The system is not able to communicate with the central
monitoring station over the primary phone line.
Telco-2 Cut – The system is not able to communicate with the central
monitoring station over the secondary phone line.
Note: Fault Icon(s) will scroll between all faults present on the system, if multiple faults
exist.