functional description
AUX Output menu is to operate the camera's peripheral devices such as lamps
and sirens through the controller and switches as well as through network
communications.
•
OUT Off 1,2 :
-
When an alarm event occurs, the output force can be terminated.
M
Connecting the power connector and GND incorrectly to the Aux terminal's NO and
COM ports may cause a short circuit and fi re, damaging the camera.
The maximum power capacity of the built-in relay is 30VDC/2A, 125VAC/0.5A, and
250VAC/0.25A. Operating the camera beyond the capacity may decrease the
camera's lifespan and damage it.
84_ functional description
NO
COM
AUX Off
NO
COM
AUX On