functional description
M
As shown in the picture above, the Alarm Input must be entered with the Open or
Closed switch signals. Supplying power without entering the signals may damage the
product.
•
P (Priority) :
Set the priority of Alarm Inputs. If more than one alarm is simultaneously
activated, the alarm with the highest priority activates before the others. Once
the alarm is canceled, the next highest priority alarm activates.
•
SEQ :
Enables setting up a sequence action for the camera in response to an alarm.
Available sequence actions are Home, Preset, Swing, Group, Tour, Trace and
A.Pan.
❋
For the Auto Pan settings, the fi rst number under the Number menu indicates
the speed while the second is the Tilt angle. (Refer below.)
ALM
IN 1
IN 2
•
MD Dwell Time :
When Motion Detection under the Preset Edit menu is selected, MD Dwell Time
performs the Tour or Group function.
While the camera is performing a sequence action, if motion is detected from a
selected preset location, the camera pauses the sequence action operation and
starts monitoring the location instead for a duration that is set under the MD
Dwell Time menu.
If the motion is no longer detectable or the duration expires, the camera aborts
the monitoring operation and then resumes the sequence action.
82_ functional description
MOD P
SEQ
NO
1
A.PAN
NC
2
A.PAN
NO
20/20
20/20
Tilt Angle
Speed