Locating Heater; Check Gas Type; Installation Items - Vanguard VP10TA Owner's Operation And Installation Manual

Infrared vent-free propane/lp gas heater
Table of Contents

Advertisement

INSTALLATION
NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system's circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
WARNING: A qualified ser-
vice person must install heater.
Follow all local codes.

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply
is not propane/LP, do not install heater. Call
dealer where you bought heater for proper
type heater.

INSTALLATION ITEMS

Before installing heater, make sure you have
the items listed below.
external regulator (supplied by installer)
piping (check local codes)
sealant (resistant to propane/LP gas)
equipment shutoff valve *
ground joint union
test gauge connection *
sediment trap
tee joint
pipe wrench
* A CSA/AGA design-certified equipment
shutoff valve with 1/8" NPT tap is an ac-
ceptable alternative to test gauge connec-
tion. The optional CSA/AGA design-certi-
fied equipment shutoff valve can be pur-
chased from your dealer. See Accessory,
page 18.
104083

LOCATING HEATER

This heater is designed to be mounted on a
wall.
WARNING: Maintain the mini-
mum clearances shown in Figure
4. If you can, provide greater clear-
ances from floor, ceiling, and
joining wall.
WARNING: Never install the
heater
• in a bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides of
the heater
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
CAUTION: This heater cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities in the air (such
as tobacco smoke, aromatic
candles, cleaning fluids, oil or
kerosene lamps, etc.) in the air
exist, may discolor walls.
IMPORTANT: Vent-free heaters add mois-
ture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-
bustion and Ventilation, pages 4 through 6.
CAUTION: If you install the
heater in a home garage
• heater pilot and burner must
be at least 18 inches above
floor
• locate heater where moving ve-
hicle will not hit it
For convenience and efficiency, install heater
where there is easy access for opera-
tion, inspection, and service
in coldest part of room
7
OWNER'S MANUAL
8"
Minimum
From
Sides Of
Heater
Left
Side
Figure 4 - Mounting Clearances As Viewed
From Front of Heater
INSTALLING HEATER TO
WALL
Marking Screw Locations
1.
Determine where you will locate heater.
WARNING: Maintain minimum
clearances shown in Figure 5. If
you can, provide greater clear-
ances from floor and joining wall.
2. Mark two mounting screw locations on
wall (see Figure 5).
10
7
/
8
Minimum To
Maintain 8"
Clearance
From Wall
Figure 5 - Mounting Screw Locations
CEILING
36"
Minimum
Right
Side
Minimum To
Top Surface
3"
Of Carpeting,
Minimum
Of Carpet
Tile Or Other
Combusti
Combustible
FLOOR
Material
7
3
/
"
"
4
1
20
Mounting
Minimum
Screw
To
Locations
Maintain 3"
Clearance
From Floor
FLOOR
Continued
/
"
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents