Vanguard VP2000BTD Owner's Operation And Installation Manual

Blue flame vent-free propane/lp gas heater

Advertisement

VENT-FREE PROPANE/LP GAS HEATER
OWNER'S OPERATION AND INSTALLATION MANUAL
VP2000BTD
VP2800BTD
20,000 and 30,000 Btu/Hr
Thermostatically-
Controlled Models
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result caus-
ing property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's in-
structions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
This appliance may be installed in an aftermarket*, permanently located, manufactured
(mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
G S O
BLUE FLAME
Save this manual for future reference.
®
S
WARNING: Improper installation,
adjustment, alteration, service, or
maintenance can cause injury or
property damage. Refer to this
manual for correct installation and
operational procedures. For as-
sistance or additional information
consult a qualified installer, ser-
vice agency, or the gas supplier.
WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it is
installed. Provisions for ad-
equate combustion and ventila-
tion air must be provided. Refer
to Air for Combustion and Venti-
lation section on page 4 of this
manual.

Advertisement

Table of Contents
loading

Summary of Contents for Vanguard VP2000BTD

  • Page 1 G S O VENT-FREE PROPANE/LP GAS HEATER OWNER’S OPERATION AND INSTALLATION MANUAL VP2000BTD VP2800BTD 20,000 and 30,000 Btu/Hr Thermostatically- Controlled Models WARNING: If the information in this manual is not followed exactly, a fire or explosion may result caus- ing property damage, personal injury, or loss of life.
  • Page 2: Safety Information

    BLUE FLAME PROPANE/LP GAS HEATER SAFETY INFORMATION WARNINGS WARNING ICON G 001 IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
  • Page 3: Product Identification

    PRODUCT IDENTIFICATION Front Panel Figure 1 - Vent-Free Propane/LP Gas Heater (Model VP2800BTD Shown) LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code ANS Z223.1, also known as NFPA 54*.
  • Page 4: Air For Combustion And Ventilation

    BLUE FLAME PROPANE/LP GAS HEATER AIR FOR COMBUSTION AND VENTILATION WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ven- tilation air. Read the following in- structions to insure proper fresh air for this and other fuel-burning appliances in your home.
  • Page 5 AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
  • Page 6 BLUE FLAME PROPANE/LP GAS HEATER AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12"...
  • Page 7: Locating Heater

    INSTALLATION NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater.
  • Page 8 18 3/4" Screws Through Last Min. Hole On Each End Floor Models VP2800BTD 7 1/4" 16" Min. Only Insert Mounting 18 3/4" Screws Through Last Min. Hole On Each End Floor Models VP2000BTD Figure 8 - Mounting Bracket Clearances 104401...
  • Page 9 INSTALLATION Continued Attaching Mounting Bracket To Wall Note: Wall anchors, mounting screws, and spacers are in hardware package. The hard- ware package is provided with heater. Attaching To Wall Stud Method For attaching mounting bracket to wall studs 1. Drill holes at marked locations using 9/64"...
  • Page 10: Connecting To Gas Supply

    If pipe is too small, undue loss of pres- sure will occur. Typical Inlet Pipe Diameters VP2000BTD 3/8" or greater VP2800BTD 1/2" or greater Installation must include equipment shutoff valve, union, and plugged 1/8" NPT tap.
  • Page 11: Operating Heater

    INSTALLATION Continued CHECKING GAS CONNECTIONS WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints.
  • Page 12 BLUE FLAME PROPANE/LP GAS HEATER OPERATING HEATER Continued LIGHTING INSTRUCTIONS 1. STOP! Read the safety information, column 3, page 11. 2. Make sure equipment shutoff valve is fully open. 3. Turn control knob clockwise Clockwise to the OFF position. 4. Wait five (5) minutes to clear out any gas.
  • Page 13: Inspecting Burner

    INSPECTING BURNER Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 19 shows a correct pilot flame pattern. Figure 20 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple. This will cause the thermocouple to cool.
  • Page 14: Troubleshooting

    BLUE FLAME PROPANE/LP GAS HEATER TROUBLESHOOTING Note: For additional help, visit DESA International’s technical service web site at www.desatech.com. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM When ignitor button is pressed, there is no spark at ODS/pilot When ignitor button is pressed, there is spark at ODS/pilot but no ignition ODS/pilot lights but flame goes out when...
  • Page 15 TROUBLESHOOTING Continued OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion Yellow flame during burner combustion Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit 104401 OWNER’S MANUAL POSSIBLE CAUSE...
  • Page 16 BLUE FLAME PROPANE/LP GAS HEATER TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. •...
  • Page 17: Specifications

    You can also write to the ad- dress listed on the back page of this manual. FLOOR MOUNTING STAND Model VP2000BTD - GA4000B Model VP2800BTD - GA4010B For locating heater on the floor, away from a wall. Complete installation instructions included.
  • Page 18: Illustrated Parts Breakdown

    BLUE FLAME PROPANE/LP GAS HEATER ILLUSTRATED PARTS BREAKDOWN VP2000BTD VP2800BTD ® 12-1 12-2 ODS/Pilot Assembly 104401...
  • Page 19: Parts List

    PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual. VP2000BTD VP2800BTD PART NUMBER FOR VP2000BTD 098304-01 098742-13 103476-01 101108-01 104189-01 098260-09 NJF-8C...
  • Page 20: Warranty Information

    WARRANTY INFORMATION Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.