Vanguard VP1000B Owner's Operation And Installation Manual

Vent-free propane gas heater

Advertisement

Quick Links

VENT-FREE PROPANE GAS HEATER
OWNER'S OPERATION AND INSTALLATION MANUAL
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service
agency, or the gas supplier.
Model: VP1000B
Save this manual for future reference.
®
®

Advertisement

Table of Contents
loading

Summary of Contents for Vanguard VP1000B

  • Page 1 • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a qualified installer, service agency, or the gas supplier. Save this manual for future reference. Model: VP1000B ® ®...
  • Page 2: Table Of Contents

    CONTENTS SECTION PAGE Safety Information ... 2 Product Identification ... 4 Local Codes ... 4 Unpacking ... 4 Product Features ... 4 Fresh Air For Combustion And Ventilation ... 5 Installing To Wall ... 9 Connecting To Gas Supply ... 13 Checking Gas Connections ...
  • Page 3: Safety Warnings

    SAFETY INFORMATION Continued 099406 WARNINGS WARNING ICON G 001 WARNING: Any change to this heater or its controls can be dangerous. 1. Use only propane gas. Do not convert heater to use different fuel type. 2. Do not place propane supply tank(s) inside any structure. Locate propane supply tank(s) outdoors.
  • Page 4: Product Identification

    PRODUCT IDENTIFICATION LOCAL CODES UNPACKING PRODUCT FEATURES Ignitor Button Front Panel Figure 1 - Vent-Free Propane Gas Heater Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1, also known as NFPA 54*.
  • Page 5: Fresh Air For Combustion And Ventilation

    FRESH AIR COMBUSTION VENTILATION 099406 WARNING ICON G 001 This heater must have fresh air for proper operation. If not, poor fuel combustion could result. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
  • Page 6 FRESH AIR COMBUSTION VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
  • Page 7 FRESH AIR COMBUSTION VENTILATION Continued 099406 VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12"...
  • Page 8 FRESH AIR COMBUSTION VENTILATION Continued VENTILATION AIR (Continued) Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors.
  • Page 9: Installing To Wall

    INSTALLING TO WALL 099406 A qualified service person must install heater. Follow all local codes. CHECK GAS TYPE Use only propane gas. If your gas supply is not propane, do not install heater. Call dealer where you bought heater for proper type heater. INSTALLATION ITEMS Before installing heater, make sure you have the items listed below.
  • Page 10 INSTALLING TO WALL Continued For convenience and efficiency, install heater • where there is easy access for operation, inspection, and service • in coldest part of room 6" Minimum From Sides Of Heater Left Side Figure 4 - Mounting Clearances As Viewed From Front of Heater INSTALLING HEATER TO WALL Marking Screw Locations 1.
  • Page 11 INSTALLING TO WALL Continued 099406 Installing Two Mounting Screws Wall anchors and mounting screws are in hardware package. The hardware Note: package is provided with heater. Attaching to wall stud method For attaching mounting screw to wall stud 1. Drill hole at marked location using 9/64" drill bit. 2.
  • Page 12 INSTALLING TO WALL Continued Placing Heater On Mounting Screws 1. Locate two keyhole slots on back panel of heater (see Figure 9). 2. Place large openings of slots over screwheads. Slide heater down until screws are in small portion of slots. Figure 9 - Location Of Keyhole Slots On Back Panel Of Heater Removing Front Panel Of Heater 1.
  • Page 13: Connecting To Gas Supply

    CONNECTING TO GAS SUPPLY 099406 A qualified service person must connect heater to gas supply. Follow all local codes. WARNING ICON Never connect heater directly to the propane supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane supply.
  • Page 14: Checking Gas Connections

    CONNECTING TO GAS SUPPLY Continued CHECKING CONNECTIONS Hold pressure regulator with wrench when connecting it to gas piping IMPORTANT: and/or fittings. 3/8" NPT Pipe Nipple Ground Joint Union Manual Shutoff Valve * From External Regulator (11" W.C. to 14" W.C. Pressure) 3"...
  • Page 15 CHECKING CONNECTIONS Continued 099406 3. Pressurize supply piping system by either using compressed air or opening propane supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5.
  • Page 16: Operating Heater

    OPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING ICON If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
  • Page 17 OPERATING HEATER Continued 099406 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 16. If you don’t smell gas, go to the next step. 5.
  • Page 18: Inspecting Burner

    OPERATING HEATER Continued INSPECTING BURNER TO TURN OFF GAS TO APPLIANCE Shutting Off Heater 1. Turn control knob clockwise 2. Press in control knob and turn clockwise Shutting Off Burner Only (pilot stays lit) 1. Turn control knob clockwise MANUAL LIGHTING PROCEDURE 1.
  • Page 19 INSPECTING BURNER Continued 099406 BURNER FLAME PATTERN Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the glass panel height. WARNING ICON G 001 If yellow tipping occurs, your heater could produce increased...
  • Page 20: Cleaning And Maintenance

    CLEANING MAINTENANCE TROUBLE- SHOOTING Note: All troubleshooting items are listed in order of operation. WARNING ICON G 001 Turn off heater and let cool before cleaning. WARNING ICON You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use.
  • Page 21 TROUBLE- SHOOTING Continued 099406 OBSERVED POSSIBLE PROBLEM CAUSE When ignitor button is 1. Gas supply turned off pressed, there is spark or manual shutoff valve closed at ODS/pilot but no 2. Control knob not in ignition PILOT position 3. Control knob not pressed in while in PILOT position 4.
  • Page 22 TROUBLE- SHOOTING Continued OBSERVED POSSIBLE PROBLEM CAUSE Burner does not light 1. Burner orifice is after ODS/pilot is lit clogged 2. Burner orifice diameter is too small 3. Inlet gas pressure is too low Delayed ignition of 1. Manifold pressure is burner too low 2.
  • Page 23 TROUBLE- SHOOTING Continued 099406 WARNING ICON G 001 If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. •...
  • Page 24: Technical Service

    TECHNICAL SERVICE SPECIFICATIONS SERVICE HINTS You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190. BTU (Variable) Type Gas Ignition Pressure Regulator Setting Inlet Gas Pressure (inches of water) Maximum Minimum Dimensions, Inches (H x W x D)
  • Page 25: Replacement Parts

    REPLACEMENT PARTS SERVICE PUBLICATIONS ACCESSORY 099406 Use only original replacement parts. This will protect your warranty coverage Note: for parts replaced under warranty. Parts Under Warranty Contact authorized dealer from whom you purchased this product. If they cannot supply original replacement part(s), call DESA International’s Technical Service Department at 1-800-323-5190 for referral information.
  • Page 26: Illustrated Parts Breakdown

    HEATER EXPLODED VIEW...
  • Page 27: Parts List

    PARTS LIST 099406 This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 25 of this manual. PART NUMBER DESCRIPTION 098304-01 Screw, #10 x 3/8" 099467-01 Front Panel Assembly 099318-04 Grill Guard 098342-01...
  • Page 28: Warranty Information

    WARRANTY INFORMATION Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. VANGUARD VENT-FREE RESIDENTIAL GAS HEATERS DESA International warrants this product and any parts thereof, to be free from defects in material and workmanship for two years from the date of first purchase, provided that the product has been properly installed, operated, and maintained...

Table of Contents