Button; Soft Row Assignment; Patch Assignment - Lexicon PCM 80 - MIDI IMPLEMENTATION DETAILS Midi Implementation Manual

Midi implementation details
Table of Contents

Advertisement

PCM 80 MIDI Implementation Details

Button

This is a bidirectional message. The following buttons are transmitted in SysEx automation mode:
Compare, Tap, Bypass. Any button will be received, and PCM 80 response will be identical to front panel
button press responses.
Byte #
1-4
5
6
7
Button SysExes may be sent in quick succession (faster than 40 ms) to mimic holds.

Soft Row Assignment

Bidirectional. Assigns a PRO-mode slot to a GO-mode soft slot.
Byte #
1-4
5
6
7
8
9
* This is the row/column that will appear in the soft row slot. A soft row position can be deassigned by setting
both row and column to 0x0f. The number of rows and columns is dependent on the current algorithm
(obtainable from a matrix dump, or from the documentation.) Slots in the Patch row cannot be assigned
to the Soft Row.

Patch Assignment

Bidirectional.
Byte #
1-4
5
6
7-8
9
10
8
ByteValue
Description
Header
0xC
Button message
0iii iiii
Button #
0 - UP
1 - DN
2 - PRG
3 - LOAD
4 - REG
5 - STORE
6 - EDIT
7 - COMPARE
8 - CTL
9 - BYP
10 - TEMPO
11 - TAP
12 - Reserved
13 - Footswitch 2
14 - Reserved
15 - Footswitch 1
0xF7
End of SysEx
ByteValue
Description
Header
0x12
SoftRowAssign
0n
Soft Row Slot (0-9)
0n
Substitute Row* (0-9)
0n
Substitute Column (0-9)
0xF7
End of SysEx
ByteValue
Description
Header
0x13
PatchAssign
0n
PatchID (0-9)
0iii iiii
Patch Source. Nibblized with less significant part first. This is the
index on the source control list. Source list indices are fixed (not
variable by preset, algorithm, or card).
0iii iiii
Patch Destination (0x7f = disconnect). All other values remain valid.
0n
Point Count (0-8) (Only the 'n' values are meaningful. Remaining
values should be set to 0.
Lexicon

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pcm 80

Table of Contents