H3C S5500-SI Complete Series Ethernet Switches
Note:
For details about LEDs on the front panel, refer to section 1.3.1
S5500-28C-SI/S5500-52C-SI Switch".
II. Rear Panel
(1): AC power input
(3): Grounding screw
(5): Extended slot 2
Figure 1-4 Rear panel of the S5500-52C-SI Ethernet switch
III. Power Supply System
The S5500-52C-SI Ethernet switch supports both AC input and RPS 12 V input. The
AC input and DC input can be used together to serve as backup for each other. In
addition, either of them can be used alone. You can use only the RPS power supply
recommended by H3C for DC input.
AC power input:
Rated voltage range: 100 VAC to 240 VAC, 50 Hz or 60 Hz
Input voltage range: 90 VAC to 264 VAC, 50 Hz or 60 Hz
RPS (DC) input:
Rated voltage range: 10.8 VDC to 13.2 VDC
IV. Cooling System
The S5500-52C-SI Ethernet switch provides four fans for heat dissipation.

1.2.3 S5500-28C-PWR-SI Ethernet Switch

I. Front Panel
The S5500-28C-PWR-SI Ethernet switch provides 24 × 10/100/1000Base-T Ethernet
ports, four Gigabit SFP Combo ports and one Console port on the front panel. Figure
1-5 shows the front panel appearance of the S5500-28C-PWR-SI Ethernet switch.
(1)
(1)
1-5
(2)
(2)
(3)
(3)
(4)
(4)
(2): DC power input
(4): Extended slot 1
Chapter 1 Product Overview
"LEDs of
(5)
(5)