Diagnosing Common Problems
Table 3-1
Symptom
No connectivity to 10/100 ports
or 10/100/1000 port.
No connectivity to
100BASE-FX port.
Catalyst 2940 Switch Hardware Installation Guide
3-2
Common Connectivity Problems and Their Solutions
Possible Cause
Incorrect or bad cable.
These are the results of no link at
both ends:
•
•
•
•
An SFP module was installed in
the switch at power on.
Note
Cable not properly installed
between switch and PC.
A crossover cable was used
when a straight-through was
required, or vice-versa.
The cable is wired
incorrectly.
STP is checking for possible
network loops.
The SFP module slots
and the 100BASE-FX
port cannot both be used
at the same time. If an
SFP module is installed
when the switch is
powered on, the
100BASE-FX port is
disabled.
Chapter 3
Troubleshooting
Resolution
•
Remove and reconnect cable
to switch and PC. Wait 30
seconds for port status LED
on switch to turn green.
To identify a crossover
•
cable, see
Figure B-12 on
page
B-9.
Verify that the cable is wired
•
correctly. See
Figure B-6 on
page B-5
through
Figure B-9 on page B-6
the correct pinouts of 10/100
cables. For the proper
application of crossover and
straight-through cables, see
the
"Cable and Adapter
Specifications" section on
page
B-5.
•
Replace it with a tested good
cable.
Wait 30 seconds for port
•
status LED to turn green.
Remove the SFP module, and
reboot the switch.
See the
"Connecting to
Note
an SFP Module" section
on page 2-12
and the
Cisco Small
Form-Factor Pluggable
Modules Installation
Notes (order number
DOC-7815160=) for
procedures on removing
an SFP module.
OL-6157-01
for