Attach Mounting Hardware; Hp Proliant Servers; Removing Cover From Proliant Ml370 Server - HP 330834-B21 - StorageWorks Ultrium 460 Tape Library Drive Module User Manual

Full-height scsi tape drives
Hide thumbs Also See for 330834-B21 - StorageWorks Ultrium 460 Tape Library Drive Module:
Table of Contents

Advertisement

Figure 4 Removing cover from ProLiant ML370 server
1. Release catch
2. Push cover back and lift off
4.
Remove the filler panel from a spare 5¼-inch bay of your server, as described in your server's
documentation. With some servers, such as the HP AlphaServer ES40, you must also remove the
half-height device divider.
5.
You are now ready to install your tape drive.

Attach mounting hardware

If your server requires special rails or other hardware to install the tape drive, mount them on the tape
drive now.
If your server does not require special mounting hardware, proceed to
CAUTION:
The Ultrium half-height drive only allows 3 mm of the engagement of the screw into the drive. If you
remove an existing drive, do not assume the screws that you remove are the correct length for your new
Ultrium drive. Always use the screws supplied with your Ultrium drive.

HP ProLiant servers

NOTE:
If mounting hardware is supplied with your tape drive, it may not be exactly the same as shown in
the illustrations.
Different models of server require different mounting methods. The server may also incorporate a locking
mechanism to hold the tape drive in place. See
Install drive
Secure the
drive.
Ultrium full-height SCSI Tape Drives
now.
23

Advertisement

Table of Contents
loading