A - 2
MC909X Mobile Computer User Guide
Technical Specifications (Continued)
Table A-1
Item
Performance Characteristics
CPU
Operating System Microsoft Windows CE 5.0 or
Memory
(RAM/ROM)
Expansion
Application
Development
Data Capture
Options
User Environment
Operating
Temperature
Storage
Temperature
Battery Charging
Temperature
Humidity
Drop
Specification
Tumble
Environmental
Sealing
ESD
MC909X-G
XScale Bulverde PXA270 processor at 624MHz
Windows Mobile 5.0 Premium
Edition
Windows CE: 64MB/64MB
Windows Mobile:
64MB/128MB
PSDK, DCP and SMDK
available through Symbol
Developer Zone Web Site
1D Standard Range scan
engine
1D Long Range scan engine
Omni-directional 1D and 2D
imaging engine reads
symbologies and captures
grayscale images and
signatures with intuitive laser
aiming.
32 °F to 104 °F (0 °C to +40 °C) ambient temperature range.
Multiple 6 ft.(1.8m) drops to concrete across operating temperature range
2,000 one-meter tumbles at room temperature (4,000 hits)
MC909X-K
Microsoft Windows Mobile 5.0 Premium and Phone Editions
Windows Mobile: 64MB/128MB
SD/MMC Card
SMDK available through Symbol Developer Zone Web Site
1D Standard Range scan engine
Omni-directional 1D and 2D imaging engine reads symbologies
and captures grayscale images and signatures with intuitive
laser aiming.
-4°F to 122°F (-20°C to 50°C)
-25°F to 160°F (-40°C to 70°C)
5% to 95% non condensing
IP64 (electronic enclosure)
+/-15kVdc air discharge
+/-8kVdc direct discharge
+/-8kVdc indirect discharge
MC909X-S