Hunter 20552 Owner's Manual And Installation Manual

Owner's manual
Hide thumbs Also See for 20552:

Advertisement

For Your Records and
Warranty Assistance
For reference, also attach your receipt or a copy
of your receipt to the manual.
__________________________________________
Model Name
__________________________________________
Model No.
__________________________________________
Date Purchased
__________________________________________
Where Purchased
Form# 42751-01
20100812
©2010 Hunter Fan Co.
Type 2 Models
Type 2 Models
Type 2 Models
Owner's Guide and Installation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Hunter 20552

  • Page 1 Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Owner’s Guide and Installation Manual __________________________________________ Model Name __________________________________________ Model No. __________________________________________ Date Purchased __________________________________________ Where Purchased Form# 42751-01 20100812 ©2010 Hunter Fan Co.
  • Page 2: Table Of Contents

    9 • Troubleshooting . . . . . . . . . . . . . . . . . . . . 17 • To reduce the risk of fire, electrical shock, or motor damage, do not use a solid-state speed control with this fan . Use only Hunter speed controls .
  • Page 3: Preparing The Fan Site

    If you want to use an existing fan site, complete the following checklist to System determine if the site is acceptable and safe for your new Hunter fan . If you cannot check off every item, prepare a new fan site as described on this page .
  • Page 4 ANSI/NFPA 70 . If your ceiling fan, go to your fan manual and continue with Section 2 • Installing the you are unfamiliar with wiring, use a Ceiling Plate. qualified electrician . 42751-01 • 08/12/10 • Hunter Fan Company...
  • Page 5 Support Brace Hunter’s patented 3-position mounting system provides you maximum installation flexibility and ease . You can install your Hunter fan in one of three ways, depending on ceiling height and your preference: Low Profile, Standard, or Angled mounting . The steps in this manual include Ceiling instructions for all three Installer’s Choice mounting methods .
  • Page 6: Getting Ready

    Parts Guide . Check for any shipping damage to the motor blade irons (if applicable) in sets, or fan blades . If any parts are missing or damaged, contact your Hunter as they were shipped . dealer or call Hunter Technical Support Department at 888-830-1326 (In Canada, call 1-866-268-1936) .
  • Page 7: Installing The Ceiling Plate

    . Do not over tighten . Flat Washer 3” Wood Screw For Angled Ceilings: Be sure to orient the ceiling plate so that the arrows printed on the ceiling plate are pointing toward the ceiling peak . 42751-01 • 08/12/10 • Hunter Fan Company...
  • Page 8: Assembling And Hanging The Fan

    Assemble securely with three low profile screws . 3-7 . Raise the fan and place the hook on the ceiling plate through the U-shaped hole in the rim . Low Profile Screw Step 3-7 U-shaped Hole 42751-01 • 08/12/10 • Hunter Fan Company...
  • Page 9: Wiring The Fan

    . 4-7 . Spread the wires apart, with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box . 42751-01 • 08/12/10 • Hunter Fan Company...
  • Page 10: Installing The Canopy And Canopy

    2 . Press firmly on opposite sides of the ring toward the canopy . The tabs will flex out releasing the trim ring from the canopy . Step 5-3 Steps 5-4 – 5-5 Canopy Screw 42751-01 • 08/12/10 • Hunter Fan Company...
  • Page 11: Assembling The Blades

    6 • Assembling the Blades Hunter fans use several styles of fan blade irons (brackets that hold the blade to the fan) . 6-1 . Install the grommets into the blades by hand . Step 6-1 (Detail) 6-2 . Place each blade between a blade iron and medallion . Install three blade screws to attach the medallion to the blade iron .
  • Page 12: Completing Your Installation With Or Without A Bowl Light Fixture

    7 • Completing Your Installation With or Without a Bowl Light Fixture Your Hunter fan comes with an integrated light fixture assembly and an optional switch housing cap and plug button . This feature gives you the option of installing the fan with OR without the included light fixture .
  • Page 13 Detail hazard or improper operation . If lights do not appear to be operating properly, see the troubleshooting section . Housing Assembly Screw 42751-01 • 08/12/10 • Hunter Fan Company...
  • Page 14 . (You may find the Light Bulbs breakaway connector on the (B10 Candelabra end of the extra chain . ) Base 60 Watt Maximum) Metal Rod Metal Disk Glass Bowl Cover Plate Breakaway Finial Connector 42751-01 • 08/12/10 • Hunter Fan Company...
  • Page 15 7-20 . Install the switch housing cap and plug button to the lower switch housing . 7-21 . Once you have uninstalled the light fixture, continue Steps 7-17 – 7-19 with step 7-6 . Male Dummy Terminal Female Dummy Terminal Plug Button Step 7-20 42751-01 • 08/12/10 • Hunter Fan Company...
  • Page 16: Fan

    . 8-6 . The blades on this fan have been treated with Hunter’s Dust Armor protection, making the blades less likely to attract dust and dirt . Use a dry or slightly damp lint free cloth to clean the In cold weather, use upward blades .
  • Page 17: Troubleshooting

    888-830-1326 (In Canada, call 1-866-268-1936) or visit us at our Web site at http://www . h unterfan . c om . Hunter Fan Company 7130 Goodlett Farms Pkwy . #400 Memphis, Tennessee 38016 42751-01 • 08/12/10 • Hunter Fan Company...