Selecting a Site

TigerStack 100 units can be mounted in a standard 19-inch equipment rack
or on a flat surface. Be sure to follow the guidelines below when choosing
a location.
N The site should:
N Make sure twisted-pair cable is always routed away from power lines,
fluorescent lighting fixtures and other sources of electrical
interference, such as radios, transmitters, etc.
N Make sure that a separate grounded power outlet that provides 100 to
240 VAC, 50 to 60 Hz, is within 8 feet of each device and is powered
from an independent circuit breaker. As with any equipment, using a
filter or surge suppressor is recommended.
NSTALLING THE
be at the center of all the devices you want to link and near a
power outlet.
be able to maintain its temperature within 0° to 50° C and its
humidity within 5% to 95%, non-condensing
provide adequate space (approximately two inches) on all sides for
proper air flow
be accessible for installing, cabling and maintaining the devices
allow the status LEDs to be clearly visible