Dell PowerEdge R610 Hardware Owner's Manual page 35

Dell server hardware owner's manual
Hide thumbs Also See for PowerEdge R610:
Table of Contents

Advertisement

Table 1-1. LCD Status Messages (continued)
Code
Text
E2110 Multibit
Error on DIMM
##. Reseat
DIMM.
E2111 SBE log
disabled on
DIMM ##.
Reseat DIMM.
E2113 Mem mirror
OFF on DIMM
## & ##.
Power cycle
AC
I1910 Intrusion
detected.
Check chassis
cover.
I1911 LCD Log full.
Check SEL to
review all
Errors.
I1912 SEL full.
Review &
clear log.
Cause
The DIMM in slot "##"
has had a multi-bit error
(MBE).
The system BIOS has
disabled memory single-bit
error (SBE) logging and will
not log anymore SBEs until
the system is rebooted.
"##" represents the DIMM
implicated by the BIOS.
The system BIOS has
disabled memory mirroring
because it has determined
one half of the mirror has
had too many errors. "##
& ##" represents the
DIMM pair implicated by
the BIOS.
System cover has been
removed.
LCD overflow message. A
maximum of ten error
messages can display
sequentially on the LCD.
The eleventh message
instructs the user to check
the SEL for details on the
events.
The SEL is full of events
and is unable to log any
more.
Corrective Actions
See "Troubleshooting
System Memory."
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory."
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory."
Information only.
Check the SEL for details
on the events.
Remove AC power to the
system for 10 seconds or
clear the SEL.
Check the SEL for details
of the error messages,
then clear the SEL.
About Your System
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge a03

Table of Contents