Table 1-1. LCD Status Messages (continued)
Code
Text
E141F CPU #
protocol
error. Power
cycle AC.
E1420 CPU Bus
parity error.
Power cycle
AC.
E1422 CPU # machine
check error.
Power cycle
AC.
E1610 Power Supply
# (### W)
missing.
Check power
supply.
E1614 Power Supply
# (### W)
error. Check
power supply.
E1618 Predictive
failure on
Power Supply
# (### W).
Check PSU.
Cause
The system BIOS has
reported a processor
protocol error.
The system BIOS has
reported a microprocessor
bus parity error.
The system BIOS has
reported a machine check
error.
Specified power supply was
removed or is missing from
the system.
Specified power supply has
failed.
A power supply fan failure,
an over-temperature
condition, or power supply
communication error has
caused the predictive
warning of an impending
power supply failure.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
Remove AC power to the
system for 10 seconds or
clear the SEL.
If the problem persists,
see "Getting Help."
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
See "Troubleshooting
Power Supplies."
See "Troubleshooting
Power Supplies."
See "Troubleshooting
Power Supplies."
About Your System
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge a03

Table of Contents