Place Product Upright And Flush Into Wall (Embedding In The Wall) - Pioneer PDP-433CMX Technical Manual

Plasma display monitor
Hide thumbs Also See for PDP-433CMX:
Table of Contents

Advertisement

Special Installation (Place product upright and flush into wall (embedding in the wall))

3.5.7 Place product upright and flush into wall (embedding in the wall)

Carefully read the following before trying to embed the unit in a wall, and make sure to observe all the limitations
specified below.
Be sure to mount the unit so that twisting, bending, or other deformation of the unit does not exceed 4 mm.
(1) Embedding in walls with space provided behind the unit (with no obstructions within a distance of 300mm
from the back surface of the unit).
A
A
<Viewed from the Right Side>
✩ Operating Temperature Restrictions
A: 0 to 370 mm
46
A
<Viewed from Above>
Temperature in space X and Y
0 to 40 °C
X (Front of the unit)
Y (Rear of the unit)