BATTERY SETUP screen

Item
Selects external DC power supply type.
EXT DC IN SEL
●AC ADPT: AC adapter
/
●BATTERY: battery
Selects battery type.
BATTERY SELECT
●PROPAC14, TRIMPAC14, HYTRON50, HYTRON140, DIONIC90, DIONIC160, NP-L7, ENDURA7,
/
ENDURA10, ENDURA-D, PAG L95, BP-GL65/95, NICD14, TYPE A, TYPE B
Near end setting
●AUTO: Automatically selects one of the following battery types selected in BATTERY SELECT.
BATTERY MODE
PROPAC14, TRIMPAC14, HYTRON50, HYTRON140, DIONIC90, DIONIC160, NP-L7, ENDURA7,
/
ENDURA10, ENDURA-D, PAG L95, BP-GL65/95
●MANUAL: Manually enter near end voltage.
PROPAC14 NEAR
Sets near end voltage for PROPAC14 (Adjustable in 0.1 V units).
●Adjustable range: 11.0 ... 13.9 ... 15.0
/
TRIMPAC14 NEAR
Sets near end voltage for TRIMPAC14 (Adjustable in 0.1 V units).
●Adjustable range: 11.0 ... 13.6 ... 15.0
/
HYTRON50 NEAR
Sets near end voltage for HYTRON50 (Adjustable in 0.1 V units).
●Adjustable range: 11.0 ... 13.7 ... 15.0
/
HYTRON140 NEAR
Sets near end voltage for HYTRON140 (Adjustable in 0.1 V units).
●Adjustable range: 11.0 ... 13.1 ... 15.0
/
DIONIC90 NEAR
Sets near end voltage for DIONIC90 (Adjustable in 0.1 V units).
●Adjustable range: 11.0 ... 13.5 ... 15.0
/
DIONIC160 NEAR
Sets near end voltage for DIONIC160 (Adjustable in 0.1 V units).
●Adjustable range: 11.0 ... 13.0 ... 15.0
/
NP-L7 NEAR
Sets near end voltage for NP-L7 (Adjustable in 0.1 V units).
●Adjustable range: 11.0 ... 13.3 ... 15.0
/
ENDURA7 NEAR
Sets near end voltage for ENDURA7 (Adjustable in 0.1 V units).
●Adjustable range: 11.0 ... 13.4 ... 15.0
/
ENDURA10 NEAR
Sets near end voltage for ENDURA10 (Adjustable in 0.1 V units).
●Adjustable range: 11.0 ... 13.3 ... 15.0
/
ENDURA-D NEAR
Sets near end voltage for ENDURA-D (Adjustable in 0.1 V units).
●Adjustable range: 11.0 ... 13.5 ... 15.0
/
PAG L95 NEAR
Sets near end voltage for PAG L95 (Adjustable in 0.1 V units).
●Adjustable range: 11.0 ... 13.5 ... 15.0
/
BP-GL65/95 NEAR
Sets near end voltage for BP-GL65/95 (Adjustable in 0.1 V units).
●Adjustable range: 11.0 ... 13.3 ... 15.0
/
NICD14 NEAR
Sets near end voltage for NICD14 (Adjustable in 0.1 V units).
●Adjustable range: 11.0 ... 13.9 ... 15.0
/
NICD14 END
Sets end voltage for NICD14 (Adjustable in 0.1 V units).
●Adjustable range: 11.0 ... 13.5 ... 15.0
/
TYPE A FULL
Sets full voltage for TYPE A (Adjustable in 0.1 V units).
●Adjustable range: 12.0 ... 15.7 ... 17.0
/
TYPE A NEAR
Sets near end voltage for TYPE A (Adjustable in 0.1 V units).
●Adjustable range: 11.0 ... 13.5 ... 15.0
/
TYPE A END
Sets end voltage for TYPE A (Adjustable in 0.1 V units).
●Adjustable range: 11.0 ... 12.8 ... 15.0
/
TYPE B FULL
Sets full voltage for TYPE B (Adjustable in 0.1 V units).
●Adjustable range: 12.0 ... 16.0 ... 17.0
/
TYPE B NEAR
Sets near end voltage for TYPE B (Adjustable in 0.1 V units).
●Adjustable range: 11.0 ... 13.1 ... 15.0
/
TYPE B END
Sets end voltage for TYPE B (Adjustable in 0.1 V units).
●Adjustable range: 11.0 ... 12.5 ... 15.0
/
Selects whether to cancel battery near end warning or not.
NEAR END CANCEL
●ON/OFF
When set to ON, the the flashing alarm and tally lamps can be stopped by pressing the DISP/MODE
/
CHK button.
Description of settings (Items in bold are factory settings.)