Problem
Possible Cause
Label Alignment is
Label Alignment
incorrect. Pressing
Length is not
FEED successively
correct. The
results in a short
default Label
label length, one-
Alignment Length is
inch.
1.00", and will
result in this
behavior when any
larger label length
is used without
setting the
appropriate length.
Label Alignment is
Label Alignment
incorrect. Pressing
Length is not
FEED successively
correct. The
results in a label
default Label
length longer than
Alignment Length is
actual, one-inch.
1.00", and will
result in this
behavior when any
larger label length
is used without
setting the
appropriate length
32
Solution
Set Label Alignment to
AUTO. Press and hold FEED
until paper moves for
automatic Label Alignment
Length measurement.
~OR~
Measure the label length and
use the Setup Menu to set the
new length. Print a Database
Configuration label to ensure
the new length has been set.
Set Label Alignment to
AUTO. Press and hold FEED
until paper moves for
automatic Label Alignment
length measurement.
~OR~
Measure the label length and
use the Setup Menu to set the
new length. Print a Database
Configuration label to ensure
the new length has been set.
E-4203/E-4204/E-4304