Cisco ME-C6524GS-8S Installation Manual page 28

Me 6500 series
Table of Contents

Advertisement

Cisco ME 6524 Ethernet Switch (ME-C6524GT-8S)
Table 1-4
Cisco ME 6524 Ethernet Switch (ME-C6524GT-8S) Specifications (continued)
Item
Shock and vibration
Acoustic noise
Physical characteristics
Dimensions (H x W x D)
Weight
Airflow
1. RU = rack units
Cisco ME 6500 Series Ethernet Switch Installation Guide
1-12
Specification
This switch complies with Network Equipment Building Systems (NEBS)
(Zone 4 per GR-63-Core) in the following areas:
Earthquake environment and criteria
Office vibration and criteria
Transportation vibration and criteria
Shock
Operational—5 G 30 ms, half-sine (IEC 68-2-27)
Nonoperational—20 G, 7.5 ms, trapezoidal
Vibration
Operational—3 Hz to 500 Hz.
Power Spectral Density (PSD)—0.0005 G
5 dB/octave roll off at each end. 0.5 hours per axis (1.12 Grms).
64 to 76 dB. International Organization for Standardization (ISO) 7779:
Bystander position operating to an ambient temperature of 86°F (30°C).
2.58 x 17.29 x 19.00 in. (6.54 x 43.92 x 48.26 cm).
Chassis requires 1.5 RU
Chassis can be mounted in 19-inch equipment racks that meet
ANSI/EIA 310-D and ETS 300-119 standards.
29.13 lb (13.21 kg).
FAN-C6524—110 CFM
To maintain proper air circulation through the switch chassis, we
Note
recommend that you maintain a minimum 6-inch (15 cm) separation
between a wall and the chassis air intake or a wall and the chassis air
exhaust. You should also allow a minimum separation of 12 inches
(30.5 cm) between the hot air exhaust on one chassis and the air
intake on another chassis. Failure to maintain adequate air space can
cause the chassis to overheat and the system to fail.
2
/Hz at 10 Hz and 200 Hz.
1
.
Chapter 1
Product Overview
OL-8900-03

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Me-c6524gt-8sMe 6524

Table of Contents