Installing batteries and turning on the power

■ Types of batteries can be used
• AA alkaline batteries (LR6) and AA nickel metal-hydride (HR15/51) only
* The R-44 cannot recharge nickel metal-hydride batteries. You must use a separate charger.
* You must specify the type of batteries in the R-44 System Settings menu item "5 System Setup" (p. 69).
The R-44 will not operate correctly if the specified battery type does not match the actual batteries.
1
Make sure that the R-44 is turned off, and disconnect the AC adaptor from the AC adaptor
jack on the R-44 side panel (left).
fig.battely.eps
2
Detach the battery cover from the bottom
panel of the R-44.
* When turning the unit upside-down, handle with care
to avoid dropping it, or allowing it to fall or tip over.
* When turning the unit upside-down, place newspapers
or magazines under the four corners or at both ends to
prevent damage to the buttons and controls. Also, you
should try to orient the unit so no buttons or controls
get damaged.
3
Insert four AA batteries into the battery
compartment, making sure to observe the
correct polarity (+ and - symbols).
4
Replace the battery cover.
5
Turn on the R-44.
6
Press the [MENU] button.
7
Use the Cursor buttons [
8
Press the [ENTER] button.
9
Using the [SCRUB/VALUE] dial, set the
to
if installing nickel metal-hydride batteries. The setting is activated as soon as you select it.
Ni-MH
10
When finished with the setting, press the [EXIT] button to return to the previous screen.
11
When you have returned to the System Menu screen, press the [EXIT] button once again.
[ENTER] will be blinking on the Display. Press the [EXIT] button to return to the Main screen if you do not
need to make additional settings.
■ Caution when using battery power on the R-44
• If you operate on battery power for an extended time, the batteries will become hot. Be careful not to
burn yourself.
• Do not mix new batteries with used batteries or mix batteries of differing types.
• If you will not be using the R-44 for an extended time, we recommend that you remove the batteries to
prevent leakage or other accidents.
• When using a USB cable to connect the R-44 to your computer, use the AC adaptor to prevent the loss
of power while the connection is active.
] [
] to select
5 System Setup
Battery Type
Getting ready to use the R-44
.
to
if installing alkaline batteries or
Alkaline