Removing A Fan - Dell 1955 Hardware Owner's Manual

Dell poweredge 1955 servers: user guide
Hide thumbs Also See for 1955:
Table of Contents

Advertisement

Removing a Fan

NOTICE:
After a fan module is removed from the system, replace it immediately to ensure proper cooling.
1 Identify the failed system fan using the back-panel fan module indicators. See Figure 1-7.
Fan 1 is the fan closest to the chassis midplane; Fan 2 is the fan closest to the fan-module handle.
2 Remove the fan module:
Press down on the fan-module release tab. See Figure 3-2.
a
Rotate the fan-module handle down to eject the fan module.
b
Slide the fan module out of the chassis.
c
Figure 3-2. Removing and Installing a Fan Module
1
1
handle
3 Remove the failed fan:
Pull up the fan-release tab. See Figure 3-3.
a
Lift up the fan lever.
b
Pull out the fan from the fan module.
c
60
Installing System Options
2
2
release tab
3
3
fan module