Configuring The Boot Drive; Removing A Hard Drive From A Hard-Drive Carrier; Installing A Hard Drive Into A Drive Carrier - Dell 1955 Hardware Owner's Manual

Dell poweredge 1955 servers: user guide
Hide thumbs Also See for 1955:
Table of Contents

Advertisement

2 Open the hard-drive carrier handle to release the drive. See Figure 3-21.
3 Slide the hard drive out until it is free of the drive bay.
If you are permanently removing the hard drive, install a blank insert.
Shutdown Procedure for Servicing a Hard Drive
NOTE:
This section applies only to situations where the server module must be powered down to service a hard
drive. In many situations, the hard drive can be serviced while the server module powered on.
If you need to power off the server module to service a hard drive, wait 30 seconds after the server
module's power indicator turns off before removing the hard drive. Otherwise, the hard drive may not be
recognized after the hard drive is reinstalled and the server module is powered on again.

Configuring the Boot Drive

The drive or device from which the system boots is determined by the boot order specified in the System
Setup program (see "Using the System Setup Program" on page 43.

Removing a Hard Drive From a Hard-Drive Carrier

Remove the four screws from the slide rails on the hard-drive carrier and separate the hard drive from the
carrier.

Installing a Hard Drive Into a Drive Carrier

1 Insert the hard drive into the hard-drive carrier with the connector end of the drive at the rear. See
Figure 3-22.
2 Align the screw holes on the hard drive with the holes on the hard-drive carrier. See Figure 3-22.
3 Attach the four screws to secure the hard drive to the hard-drive carrier. See Figure 3-22.
Installing System Options
91