Configuring A Normally Closed Supervised Alarm; Configuring Non-Supervised Alarms (Inputs 1 Through 7); Configuring A Normally Open Non-Supervised Alarm - Bosch VG4-161-CC0 Installation Manual

Vg4 modular camera series
Table of Contents

Advertisement

VG4 Modular Camera Series
3.
6.2.2

Configuring a Normally Closed Supervised Alarm

1.
2.
3.
6.3

Configuring Non-supervised Alarms (inputs 1 through 7)

You can configure alarms 3 through 7 as non-supervised Normally Open (N.O.) or Normally
Closed (N.C.) alarms.
6.3.1

Configuring a Normally Open Non-supervised Alarm

1.
Bosch Security Systems, Inc.
From the AutoDome main menu, select Alarms Setup>Inputs Setup, and set the Alarm
Input # to N.O.S. See the table below for contact and condition details.
AutoDome Programmed N.O.S.
Contact
Alarm Condition
Open
Normal
Closed
Alarm
Cut or brake
Tamper
Install a 2.2 K end-of-line resistor in the alarm circuit.
Connect the alarm wires to input 1 or 2 (pin 5 or 6) and to the ground (pin 7) at the
AutoDome.
2.2K
Figure 6.2 N.C.S. - Normally Closed Supervised Connections
1
Dry Contact
2
Alarm 1 or 2 only (Pin 5 or 6)
From the AutoDome main menu select Alarm Setup>Inputs Setup, and set Alarm Input #
to N.C.S. See the table below for contact and condition details.
AutoDome Programmed N.C.S.
Contact
Alarm Condition
Open
Alarm
Closed
Normal
Short
Tamper
Connect the alarm to the appropriate input (1 through 7) and ground at the AutoDome.
Figure 6.3 N.O. - Normally Open Non-supervised Connections
1
Dry Contact
2
Alarm Inputs 1 to 7
Installation Manual
3
Dome Connector
4
Ground (Pin 7)
3
Dome Connector
4
Ground
Alarms and Relay Connections | en
F.01U.216.010 | 8.0 | 2011.02
99