Power Supply Box Connections - Bosch VG4-161-CC0 Installation Manual

Vg4 modular camera series
Table of Contents

Advertisement

54
en | Installing Roof Parapet and Pipe Mounts
3.4.3

Power Supply Box Connections

The following figure is a detailed illustration of the Roof or Pipe Mount Power Supply Box,
which includes the fuse specifications.
1
2
3
4
WARNING!
Fuse replacement by qualified service personnel only. Replace with same type fuse.
Volts
24 V
115 V
230 V
F.01U.216.010 | 8.0 | 2011.02
P101
CONTROL
24V NC 24V
IN/OUT
1 2 3
P106
GND T XD RXD
C+ C-
6 5 4 3 2 1
Ground Screw
Transformer (115/230 VAC Modes) 6
In/Out to Dome
24 VAC to Dome Interface Board
Fuse Specifications
XF101 Mains
XF102 Camera
T 5.0 A
T 1.6 A
T 0.8A
Installation Manual
J102
(LED)
CONTROL
TO DOM E
M M
P105
GND T XD RXD
C+ C-
6 5 4 3 2 1
3
5
Power In
In/Out; 1/2 in. (15 mm) NPS Fitting
7
Power In; 3/4 in. (20 mm) NPS Fitting
8
Control Data and Video In/Out; 3/4 in. (20 mm)
NPS Fitting
XF103 Heater
T 2.0 A
T 3.15 A
T 2.0 A
T 3.15 A
T 2.0 A
T 3.15 A
VG4 Modular Camera Series