Rs-232 Baud Rate; Rs-232 Word Length: Data Bits, Stop Bits, And Parity - Honeywell 4600RSF051CE User Manual

Commercial/retail/industrial area imager
Table of Contents

Advertisement

RS-232 Baud Rate

Baud Rate sends the data from the imager to the terminal at the specified rate.
The host terminal must be set for the same baud rate as the imager.
Default = 38,400.
300
1200
4800
19200
57,600

RS-232 Word Length: Data Bits, Stop Bits, and Parity

Data Bits sets the word length at 7 or 8 bits of data per character. If an applica-
tion requires only ASCII Hex characters 0 through 7F decimal (text, digits, and
punctuation), select 7 data bits. For applications which require use of the full
ASCII set, select 8 data bits per character. Default = 8.
Stop Bits sets the stop bits at 1 or 2. Default = 1.
2 - 10
600
2400
9600
* 38400
115,200