Connect the cable to the indoor unit
1. The inside and outside connecting
cable can be connected without
removing the front grille.
2. Connecting cable between indoor
unit and outdoor unit shall be
approved polychloroprene
sheathed flexible cord, type
designation 16AWG or heavier
cord.
3. Lift the indoor unit panel up,
remove the electrical box cover by
loosening the screw.
4. Ensure the colour of wires of
outdoor unit and the terminal Nos.
are the same to the indoors
respectively.
5. Wrap those cables not connected
with terminals with insulation
tapes, so that they will not touch
any electrical components. Secure
the cable onto the control board
with the cord clamp.
Electrical work
19
C C able
Code wire
Terminal block of indoor unit
N(1) 2
3
To Outdoor Unit
Electrical box
cover