Omron V7-IP65 Quick Start Manual page 42

Compact sensorless vector inverter
Hide thumbs Also See for V7-IP65:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 31
n050-n056 Multi-function input (S1-S7)
Multi-function output (MA-MB-MC)
n057
Multi-function analog output (AM-AC):
n066
0: Output frequency (10V/Max, freq.)
1: Output current (10V/Inverter rated current)
Carrier frequency
n080
DC injection braking current
n089
DC injection braking at stop
n090
DC injection braking at start
n091
Stall prevention during deceleration:
n092
0: Enabled
1: Disabled
0 to 35
0 to 21
0 to 6
1 to 4 (2.5 - 10kHz)
7 to 9
(Proportional to output freq.)
0 to 100%
0.0 to 25.5sec
0.0 to 25.5sec
0.1
-
1
0
Depending on model
50%
0.5sec
0.0sec
0
EN-13