SECTION 2
Installation and Connections/Wiring

■ RS-232C Port

The method for connecting a CIDRW Controller or host device via the RS-232C port is explained here.
To the RS-232C port
• Connector
The RS-232C port of the Amplifier Unit is a D-SUB, 9-pin connector. The pin arrangement is shown
below.
Pin No.
Signal name
1
2
Receive data
3
Send data
4
5
Signal ground
6
7
Request send
8
Send enable
9
CIDRW System
32
User's Manual
Amplifier Unit
Amplifier Unit
To the RS-232C port
Symbol Signal direction
NC
RD
Input
SD
Output
NC
SG
NC
RS
Output
CS
Input
NC
CIDRW Controller
Host
1 2 3
4 5
The connector rim has electrical continuity with the GR (frame
6 7 8 9
ground) terminal in the dedicated power supply connector.
Remarks
Not connected
Not connected
Not connected
Always ON during normal operation
Not connected
To ID port
To the RS-232C port