Omron SFC - INTRODUCTION GUIDE Introduction Manual page 43

Table of Contents

Advertisement

2-9 Simulated Operation Test
Right-click the Ticket Acceptance Flag
transition, and select Force Transition - On
from the pop-up menu.
The active status will be transferred from the
Issue Ticket step to the Gate Open step.
2
Double-click the Opening Gate action.
Check the execution status of the action
program in the program view.
Click the Ticket Issuance action again.
In the program view, confirm that outputs
10.00 (Issue Ticket) and 20.00 (Ticket
Issuance Message) are both turned OFF.
3 Test the operation of the actions.
Force-set the Gate Fully Open Flag
transitions.
Check the operation of the actions as the
steps become active/inactive.
Since the Vehicle Sensor in the Gate Passed
transition program is OFF, the Gate Passage
transition condition is satisfied. Active status
will be transferred immediately from the Pass
Gate step to the Gate Close step.
The action block in the Gate Close step will
be triggered 3 seconds after the transition.
When the Gate Fully Closed Flag transition
condition is satisfied, the Initial Step will
become active once again.
Test the program again in the same manner
to double-check.
The program operation test is now completed.
2-33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sfc

Table of Contents