(6) POST Error Process Settings
Function
Mode
Retry Counter
(Mode: Available only when
Retry is selected.)
Timer
(Mode: Available only when
Retry or Auto is selected.)
Auto Resume
(Mode: Available only when
Retry is selected.)
Power Off
(Mode: Available only when
Retry is selected.)
Note: The settings in the table are initial values.
Setting
[Normal]
Selects the operation that will be
Retry
performed when a POST error occurs.
Auto
Normal: Shuts down after an error
occurs.
Retry: Shuts down when the number of
retries is exceeded or turns the power
OFF.
Auto: Ignores the error and resumes
startup.
1
Sets the number of retries from 1 to 15.
2
[3]
4
.
.
14
15
1
Sets the amount of time before the next
[3]
retry after a POST error occurs.
5
10
15
[Enabled]
Selects whether to ignore the error
Disabled
when the number retries for a POST
error is exceeded and resumes startup.
Enabled
Selects whether to turn the power OFF
[Disabled]
when the number of retries is exceeded
for a POST error.
Appendix 1 BIOS Setup