Charger Ratings and Specifications
4-3
Charger Ratings and Specifications
4-3-1
General Specifications of the RB-C2001 Charger
Item
Operating voltage
Charging
Charging voltage/current
specifica-
Status indicators
tions
Ambient operating temperature
Ambient storage temperature
Operating humidity
Weight
Applicable laws and standards
66
100 to 240 VAC, 50/60 Hz
8.4 V/1 A
LED indicators are used for the following status.
• No battery or pre-charge: Not lit
• Charging normal: Lit red
• Charging complete: Lit green
• Error detected: Flashing red
0 to 40°C
−20 to 60°C
20% to 85% (with no condensation)
0.15 kg max.
• Electrical Appliance and Material Safety Law
• UL 1310
• IEC 60950
• EN 55022 Class B
Specifications
Section 4-3