Omron H8GN - V1.02 Manual page 18

Preset counter/timer
Table of Contents

Advertisement

■ Parameters
Power ON
Adjustment
Operation level
level
Key
less than 1 s.
Key
Key
3 s. min.
1 s. min.
Initial
Communications
setting
setting level
level
Key
less than 1 s.
Key
Password input
1 s. min.
set value " 169"
Advanced
function setting
level
Advanced function setting level
Parameter
initialization
Use SV-
bank
When
Use
counter
totalizing
selected
counter
Display
auto-return
time
Move-to-
protect-
level time
Note : The parameters shown in reverse video are
the default settings.
C-76
Preset Counter/Timer
+
Keys
3 s. min. (default value)
Protect level
+
Keys 1 s. min.
Operation in progress
Operation stopped
No display due to model and settings
No display due to model and settings
Level change
Key 1 s. min.
: Initialize
: Not initialize
: Use
: Not use
: Use
: Not use
: No auto-return
: 1 to 99 s.
: 3 to 30 s.
See note 3.
H8GN
Power ON
Key 1 s. min.
Operation level
Key 3 s. min.
PV/SV
PV
When
totalizing
Totalizing
counter
count value
selected
When
SV-bank
using
SV-bank
Initial setting level
Password input
( 169) and move
Counter/
Timer
selection
When
Input
counter
mode
selected
Time
range
When
timer
selected
Timer
mode
When
Output
counter
mode for
selected
counter
When
Output
timer
mode for
selected
timer
When the
above C*,
Output
K*, A*, or
time
B* mode
selected
Counting
When
speed
counter
selected
Input signal
width (start,
reset, gate)
Decimal
When
point
counter
position
selected
Prescale
value
When
increment
Input
or
signal
decrement
edge
selected in
counter
input mode
Move to advanced function setting level.
Key less than 1s.
See note 1.
Press the
Key to
reset the PV.
Press the
Key to reset
the totalizing count value and
the PV simultaneously
: SV 0
: SV 1
: SV 2
: SV 3
Key 1 s. min.
: Counter
: Timer
: Increment
: Decrement
: Individual
: Quadrature
See note 2.
: Elapsed time
: Remaining time
: N
: F
: C*
: K*
: A*
: B*
: D
: E
: F
: Z
: 0.01 to 99.99 s
Counter
Timer
: 0.00 to 99.99 s
Output will be held if output time is 0.
Output time cannot be set to 0 when
counter function is selected.
: 30 Hz
: 5 kHz
: 20 ms
: 1 ms
: 0
: 0.0
: 0.00
: 0.000
: 0.001 to 9.999
: Counting on rising edge
: Counting on falling edge