Specifications - Omron G3PA Manual

Solid state relays
Hide thumbs Also See for G3PA:
Table of Contents

Advertisement

Specifications

■ Ratings (at an Ambient Temperature of 25 C)
Input
Model
Rated voltage
G3PA-210B-VD
5 to 24 VDC
G3PA-220B-VD
G3PA-240B-VD
G3PA-260B-VD
G3PA-210BL-VD
5 to 24 VDC
G3PA-220BL-VD
G3PA-240BL-VD
G3PA-260BL-VD
G3PA-210B-VD
24 VAC
G3PA-220B-VD
G3PA-240B-VD
G3PA-260B-VD
G3PA-420B-VD
12 to 24 VDC
G3PA-430B-VD
G3PA-420B-VD-2
G3PA-430B-VD-2
G3PA-450B-VD-2
Output
Model
Rated load voltage
G3PA-210B(L)-VD
24 to 240 VAC (50/60 Hz)
G3PA-220B(L)-VD
G3PA-240B(L)-VD
G3PA-260B(L)-VD
G3PA-420B-VD
180 to 400 VAC (50/60 Hz)
G3PA-430B-VD
G3PA-420B-VD-2
200 to 480 VAC (50/60 Hz)
G3PA-430B-VD-2
G3PA-450B-VD-2
Refer to Engineering Data for further details.
Operating Voltage
Input current
range
impedance
4 to 30 VDC
7 mA max.
4 to 30 VDC
20 mA max.
19.2 to 26.4 VAC
1.4 k
9.6 to 30 VDC
7 mA max.
Load voltage range
19 to 264 VAC (50/60 Hz)
150 to 440 VAC (50/60 Hz)
180 to 528 VAC (50/60 Hz)
Must operate voltage
4 VDC max.
4 VDC max.
20%
19.2 VAC max.
9.2 VDC max.
Applicable load
Load current
0.1 to 10 A
0.1 to 20 A
0.5 to 40 A
0.5 to 60 A
0.5 to 20 A
0.5 to 30 A
0.5 to 20 A
0.5 to 30 A
0.5 to 50 A
Solid State Relays
Voltage level
Must release voltage
1 VDC min.
1 VDC min.
4.8 VAC min.
1 VDC min.
Inrush current
150 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
G3PA
J-23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents