Modular temperature controller e5zn series
Hide thumbs Also See for E5ZN:
Table of Contents

Advertisement

■ Characteristics
Indication
accuracy
Transfer output
Hysteresis
Proportional band (P)
Integral time (I)
Derivative time (D)
Control period
Manual reset value
Alarm setting range
Sampling period
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Enclosure rating
Memory protection
Weight
Approved standards
(See note 4.)
Note: 1. The indication accuracy for T and N thermocouples at 100×C, and for U and L thermocouples is 2×C 1 digit max. There is no speci-
fication for the indication accuracy for the B thermocouple used at 400×C max. The indication accuracy for R and S thermocouples at
200×C max. is 3×C 1 digit max.
2. The transfer output accuracy for 0 to 4 mA when 0 to 20 mA DC is selected is 0.5% FS 0.7 mA. The transfer output accuracy for 0 to
1 V when 0 to 5 VDC is selected is 0.5% FS 0.175 V.
3. "EU" stands for "Engineering Unit."
4. In order to satisfy the EN61326 Class A standard for conducted emissions, install a noise filter (Densei-Lambda MXB-1206-33 or equiv-
alent) in a DC power line as close to the E5ZN as possible.
I-132
Modular Temperature Controller
Thermocouple: (Indicated value 0.5% or 1×C, whichever is greater) 1 digit max. (See note 1.)
Platinum resistance thermometer: (Indicated value 0.5% or 1×C, whichever is greater) 1 digit max. (See
note 1.)
Analog input: 0.5% or 1 digit max.
CT input: 5% FS 1 digit max.
Accuracy: 0.5% FS (See note 2.)
0.1 to 999.9 EU (in units of 0.1 EU)
(See note 3.)
0.1 to 999.9 EU (in units of 0.1 EU)
(See note 3.)
0 to 3,999 s (in units of 1 s)
0 to 3,999 s (in units of 1 s)
1 to 99 s (in units of 1 s)
0.0 to 100.0% (in units of 0.1%)
1,999 to 9,999 (Position of decimal point depends on input type.)
500 ms
20 MW min. (at 500 VDC)
600 VAC for 1 minute at 50 or 60 Hz (between unlike terminals of charged parts)
2
10 to 55 Hz, 10 m/s
for 2 hrs each in X, Y, and Z directions
2
150 m/s
max., 3 times each in X, Y, and Z directions
Temperature Controller: IP00
Terminal Unit: IP00
EEPROM (non-volatile memory) (Number of write operations: 100,000)
Temperature Controller: Approx. 90 g
Terminal Unit (18): Approx. 80 g
Terminal Unit (24): Approx. 100 g
UL File No.:
CSA File No.:
CE EMS:
ESD
REM field
Fast transient
Surge immunity EN61326, EN61000-4-5 (line to ground: 2 kV/DC power
Conducted RF
EMI:
Radiated
E5ZN
E200593
203889-1140084
EN61326, EN61000-4-2 (4 kV/contact, 8 kV/air)
EN61326, EN61000-4-3 (10 V/m)
EN61326, EN61000-4-4 (2 kV/DC power, 1 kV/I/O)
line to line:
EN61326, EN61000-4-6 (10 V)
EN61326 Class A
1 kV/I/O
1 kV/DC power)