5. Setting Functions in SET Mode

* The default settings are shown in the transition boxes between functions.
Teaching: Refer to 4. Teaching the Threshold Value (SET Mode) on page 20.
Set the Mode Selector
to SET.
SET
Operation
Refer to 1. Setting the Operation Mode on page 19.
mode
UP
MODE
Changes the setting.
UP
MODE
Timer
(To use the timer function)
UP
MODE
Enables the timer.
Time
MODE
Display
(To change the display method)
switch
UP
MODE
MODE Key
(To change the function of the MODE key during operation)
UP
MODE
Power tuning
target value
UP
MODE
Display
orientation
UP
MODE
Light Level and Threshold Display
MODE
Switch to desired
function.
Light ON
Dark ON
DOWN
Super-high-speed mode
Standard mode
DOWN
High-resolution mode
Timer disabled
OFF-delay timer
DOWN
ON-delay timer
One-shot timer
Setting range: 1 to 5,000 ms
1 to 20 ms 1-ms increments
UP
DOWN
20 to 200 ms
200 ms to 1 s
1 to 5 s
DOWN
*1
Executes power tuning.
Executes a zero reset.
DOWN
Refer to 2. Adjusting the Power
(RUN Mode) on page 19.
Setting range: 100 to 3,900 (increments of 100)
Maximum power
DOWN
(To reverse the orientation of the display.)
Normal display
Up/down reversed display
DOWN
*1 The display will be switched as shown below.
CH1 light level
CH2 light level
5-ms increments
100-ms increments
1-s increments
Light level Threshold
% light level Threshold
L-PE
L-BT
Detection status
PEAK
Light level
Fixed
interval
Light level Peak light level
Light level
Channel
E3X-MDA
Light levels for channels 1 and 2
The incident light level and the threshold value.
The incident light level as a percentage of the
threshold value and the threshold value.
The incident light peak level and no incident light
bottom level.
D-BT
(Refreshed when output turns ON or OFF.)
The min. incident light peak level and max. incident
light bottom level, showing min. width of light level
D-PE
change. (Refreshed when output turns ON/OFF
ten times.)
Analog bar display. The current detection status is
displayed as an analog bar. The bar will lengthen
from the right as ON status is reached.
(ON: Red; OFF: Green)
The current incident light level and the peak
incident light level.
The incident light level and the channel.
Super Dual Fiber Sensors
21