Limited-reflective Fiber Units
Features
Appearance
Suitable for posi-
tioning liquid crystal
glass
Suitable for posi-
tioning liquid crystal
glass
Suitable for posi-
tioning liquid crystal
glass (Resists
300 ° C)
Liquid crystal glass,
mounting detec-
tion, small
Detects wafers and
small differences in
height; (operating
ambient tempera-
ture: − 40 ° C to
105 ° C); degree of
protection:
IEC60529 IP50
Detects wafers and
small differences in
height; degree of
protection:
IEC60529 IP50
* Values are sensed for white paper (standard sensing object).
Applicable
Sensing distance (mm)*
Amplifier Unit
E3X-MDA
0 to 15
0 to 15
0 to 15
E3X-MDA
4 to 12
4 to 12
4 to 12
E3X-MDA
5 to 18
5 to 18
5 to 18
E3X-MDA
0 to 4
0 to 4
0 to 4
E3X-MDA
4±2
4±2
4±2
E3X-MDA
7.2±1.8
7.2±1.8
7.2±1.8
E3X-MDA
3.3
3.3
3.3
E3X-MDA
3.3
3.3
3.3
Standard object
(min. sensing ob-
ject: Gold wire)
100 × 100
Soda glass with re-
flection factor of 7%
25 × 25
(0.005-mm dia.)
E3X-MDA
Super Dual Fiber Sensors
Model
Permissi-
ble bend-
ing radius
E32-L16
25 mm
E32-L56E1
35 mm
E32-L56E2
E32-L66
25 mm
E32-L24S
10 mm
E32-L24L
10 mm
E32-L25L
E32-L25
25 mm
E32-L25A
15