Amplifier Unit Connectors
Installation
Installation Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit
until it clicks into place.
2. Join Amplifier Units together as required after all the Master
and Slave Connectors have been inserted.
3. Apply the supplied seal to the non-connection surface of the
master/slave connector.
Sticker
Note: Apply the seal to the grooved side.
Removing Connectors
1. Slide the slave Amplifier Unit for which the Connector is to
be removed away from the rest of the group.
2. After the Amplifier Unit has been separated, press down on
the lever on the Connector and remove it. (Do not attempt
to remove Connectors without separating them from other
Amplifier Units first.)
A-448
Insert
Sticker
Press down
Lever
Remove
Mounting End Plate (PFP-M)
Depending on the installation type, an Amplifier Unit may
move during operation. In this case, use an End Plate.
Before installing an End Plate, remove the clip from the mas-
ter Amplifier Unit using a nipper or similar tool.
The sensor bottom is also equipped with the clip removing
mechanism.
1. Insert the clip to be removed into the slit underneath the clip
on another Amplifier Unit.
2. Remove the clip by rotating the Amplifier Unit.
Rotate
Pull Strengths for Connectors (Including Cables)
E3X-CN11: 30 N max. E3X-CN12: 12 N max.