Precautions For Correct Use - Omron E3JM Datasheet

Multi voltage photoelectric sensor in plastic housing with timer function
Hide thumbs Also See for E3JM:
Table of Contents

Advertisement

Precautions
! Warning
This product is not designed or rated for ensuring safety of persons.
Do not use it for such purposes.
Connections
Through-beam Models
Emitter
2
1
5
4
3
Sensing
12 to 240 VDC
object
24 to 240 VAC
Retro-reflective Models
Receiver
Sensing
E39-R1
object
Reflector
Diffuse-reflective Models
NO
Tb
Receiver
Sensing
object

Precautions for Correct Use

Switch Configuration
Models without Timer
MODE
0
1
D·ON
L·ON
Switch for operating mode
6
NO
COM
NC
Tb
Tc
Ta
Receiver
3 4 5
1 2
Power
source
12 to 240 VDC
24 to 240 VAC
NO
COM
NC
Tb
Tc
Ta
3 4 5
1 2
12 to 240 VDC
24 to 240 VAC
COM
NC
Tc
Ta
3 4 5
1 2
12 to 240 VDC
24 to 240 VAC
Adjustment
Through-beam Models
For a E3JM with the timer function, the indicator will be lit when
incident light is received while the mode is switched to Light-ON,
and the indicator will be lit when light is interrupted while the mode
is switched to Dark-ON.
Move the Emitter and Receiver horizontally and vertically, and
locate them to the center of the range in which the Receiver indi-
cator is lit.
Retro-reflective Models
The indicator of the Retro-reflective Model with the timer function
is lit in the same way as for the Through-beam Model.
As with the Through-beam Model, adjust the Reflector and Sen-
sor. Since the directional angle of the E3JM Retro-reflective
Model is 1 to 5 degrees, pay careful attention when adjusting the
Sensor.
Diffuse-reflective Models
The indicator of the Diffuse-reflective Model with the timer func-
tion is lit in the same way as for the Through-beam Model.
Sensing object
is present.
(A) Operation
Sensitivity
1. If a sensing object is present as shown above, turn the sensi-
tivity adjuster clockwise to increase the sensitivity. Point (A) is
where the indicator is lit.
2. Remove the sensing object and turn the adjuster clockwise.
Point (B) is where the indicator is lit by background objects.
3. Turn the adjuster counterclockwise to decrease the sensitivity,
starting from the point (B). Point (C) is where the indicator is
lit.
4. The center point between the point (A) and point (C) is the
optimum position. If the indicator is not lit by the background
object at the maximum sensitivity, set to the center point
between the point (A) and the maximum sensitivity.
Note: The sensitivity adjuster may be damaged if an excessive force is
applied.
Models with Timer
MODE
0
1
D·ON
L·ON
SW1
TIMER
SW2
Switch for operating mode
Switch for timer mode
Multi voltage photoelectric sensor
Sensing object
is not present.
(C) Release
(B) Operation
Sensitivity

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents