Comparison Of Functions Between Conventional Support Software And Cx-One - Omron CX-ONE - INTRODUCTION GUIDE Introduction Manual

Fa integrated tool package
Table of Contents

Advertisement

3. Comparison of Functions Between Conventional Support Software and
3. Comparison of Functions Between Conventional Support Software and
CX-One (1/2)
CX-One (1/2)
Function
Handling of CX-Programmer's I/O Table
window
Initial setting of CPU Bus Units and
Special I/O Units (assignment DM,
assignment relay, CPU Bus Unit System
setting)
Network
Ethernet
CPU Bus Unit
setting
System Setting for
Ethernet Unit
Ethernet network
monitor
Controller
Controller Link Unit
Link
soft-switch setting
Controller Link Data
Link (manual or
automatic) setting
Controller Link
network monitor
Conventional Support Software
Only mounted Unit position information
Shows used position/size only
(only head address and size of used area
in CIO area are displayed)
Assignment DM setting of CPU Bus
Units and Special I/O Units is unavailable.
Configuring four-digit hexadecimal or
other value for each address by referring to
assignment DM area on the manual using
PLC memory as with universal DM area.
(Direct setting in many cases)
* It is necessary to configure values while
checking addresses based on Unit number.
And the data are not saved as parameter
data for each Unit (only as DM data for a
CPU Unit).
Setup data can be handled in the same
way as other I/O memory areas for saving
into a CXP project file or as a data file of
file memory.
By [Unit Setting] in the online CX-
Programmer's I/O Table.
No tool for monitoring Ethernet network.
By right-clicking on a Controller Link Unit of
the I/O Table in the online CX-Programmer
and selecting [Software Switch Setting].
By CX-Net (Data Link Component) in CX-
Programmer.
No tool for monitoring Controller Link
network.
CX-One
In addition to traditional functions, the
following functions are available:
Used as a setting terminal of CPU Bus
Units and Special I/O Units
Used as a terminal to start each Unit's
Support Software
By right-clicking a target Unit on the I/O
Table and selecting [Unit Setup],
configuration is available of CPU Bus Units
and Special I/O Units parameter (mainly
allocation DM) setting without referring to a
manual in the following dialog box.
* Setting is available using item names
without recognizing addresses. Also, data
can be saved/read as a parameter setting
data file for each Unit.
Setup data can be saved in a parameter
setting data file for each Unit, or into a CXP
project file for entire Units' parameter settings.
By right-clicking on an Ethernet Unit of the
I/O Table and selecting [Unit Setup]. Can be
saved as a parameter as with other CPU Bus
Units and Special I/O Units.
Ethernet network connection device can be
monitored by CX-Integrator.
By right-clicking on an Controller Link Unit of
the I/O Table online or offline and selecting
[Unit Setup].
Trough a Data Link Component by selecting
[Tools] > [Start Data Link] from CX-Integrator.
Controller Link network connection device
can be monitored by CX-Integrator.
Controller Link diagnosis tool can be started
as well (By selecting [Tools] > [Controller
Link Tool] > [Network Diagnosis] from online
CX-Integrator).