If problems occur ...

Error checklist

Problem
No operation
indication
Transmitter
cannot be
switched off/
Settings cannot
be changed
Receiver:
No RF signal
Weak signal
Audio signal
has a high level
of background
noise
Audio signal is
distorted
If problems occur that are not listed in the above table or if the
problems cannot be solved with the proposed solutions, please
contact your local Sennheiser agent for assistance.
28
Possible cause
Batteries are flat or
inserted incorrectly,
battery pack is flat
Lock mode is activated
Transmitter and
receiver are not on the
same channel
Transmitter is out of
range
Antenna signal is
attenuated
Transmitter's input
attenuation is adjusted
too high
Receiver's output level
is adjusted too low
Transmitter's input
attenuation is adjusted
too low
Receiver's output level
is adjusted too high
Possible solution
Replace the batteries or
check if they are
inserted correctly or
recharge the battery
pack
Deactivate the lock
mode (see
"Deactivating the
autolock function
temporarily" on page
16)
Set transmitter and
receiver to the same
channel
Check the squelch
threshold setting
or reduce the distance
between receiving
antenna and
transmitter
Do not clasp the
antenna section
See "Adjusting the
microphone sensitivity
– ATTEN" on page 25
Increase the line output
level
See "Adjusting the
microphone sensitivity
– ATTEN" on page 25
Reduce the line output
level