Connection - Smeg SI3633B Manual To Installation And Use

Table of Contents

Advertisement

1 1 / INSTALLING YOUR APPLIANCE
• •

CONNECTION

These hobs must be connected to the mains
using a socket in compliance with publication
IEC 60083 or an all-pole circuit-breaker device in
compliance with the installation rules in force.
Your appliance should be positioned so that
the mains switch is accessible.
When power is first supplied to your hob, or
after an extended power cut, an indicator light
will appear on the control panel. Wait for
30 seconds approximately until this informa-
tion disappears before using your hob (This
display is normal and it is intended, if applica-
ble, for your after-sales service. In all cases,
the user of the hob should disregard it).
Warning
If the cable is damaged it must be
replaced by the manufacturer, its after-
sales service or a person with a similar
qualification to prevent danger.
• Hook-up of 220-240V
Blue
Brown
N N
32A
~
Black-grey
Green/yellow
L L
• Hook-up of 400V 2N
Separate the 2 phase wires (L1 and L2) before
connection.
Black-grey
Brown
Blue
N N
N N e e u u t t r r a a l l
For a 400 V 2N triphase connection, if your
hob malfunctions, check that the neutral
conductor is properly connected.
• Hook-up of 2x230V 2L+2N
Separate the wires before connection.
Black-grey
Brown
Blue
N N 1 1
N N e e u u t t r r a a l l
• Hook-up of 400V 3
19
- 16A
~
Green/yellow
L L 1 1 L L 2 2
L L i i v v e e
E E a a r r t t h h
- 16A
~
Green/yellow
N N 2 2
L L 1 1 L L 2 2
E E a a r r t t h h
L L i i v v e e
- 16A
~
EN