Instructions For The Installer - Smeg SCB 60 CSV8 Manual

Table of Contents

Advertisement

POSSIBLE CONNECTION
380
-
380
-
220
-
• Use H05V2V2-F cables resistant to at least 90°C.
• The values indicated above refer to the cross-section of the internal conductor.
• The tightening torque of the screws of the terminal supply wires must be 1.5 - 2 Nm.
• The aforementioned power cables are sized taking into account the coincidence factor (in compliance
with standard EN 60335-2-6).
46

Instructions for the installer

TYPES
415
V
3N~
415
V
2N~
240
V
1N~
CABLE TYPE
(if not present)
5-pole
5 x 1.5 mm²
4-pole
4 x 2.5 mm²
3-pole
3 x 4 mm²
H05V2V2-F
H05V2V2-F
H05V2V2-F