Installing The Appliance - Smeg SC341GX-8 Manual

Table of Contents

Advertisement

Instructions for the installer

11. INSTALLING THE APPLIANCE

11.1 Electrical connection
The identification plate bearing the technical data, serial number and brand
name is visibly positioned on the appliance.
Do not remove this plate for any reason.
The appliance must be connected to earth in compliance with electrical system
safety regulations.
If a fixed connection is being used, fit the power line with an omnipolar circuit-
breaker in accordance with the installation rules, located in a position which is
easy to reach and near the appliance.
If a plug and socket connection is being used, make sure that the plug and
socket are compatible. Avoid use of adapters and shunts as these could cause
overheating and risk of burns.
Operation at 220-240 V~: use a H05V2V2-F type
2
three-core cable (3 x 1.5 mm
).
The end to be connected to the appliance must
have an earth wire (yellow-green) at least 20 mm longer than the others.
WARNING: The values indicated above refer to the cross-section of the
internal conductor.
11.2 Room ventilation
The room containing the appliance should have an air supply in accordance with
the standards in force. The room where the appliance is installed must have
enough air flow as required for the regular combustion of gas and by the
necessary air exchange of the same room. The air vents, protected by grills,
must be suitably dimensioned in compliance with the current standards and
positioned so that no part of them is at all obstructed. The cooker must be kept
adequately ventilated in order to eliminate the heat and humidity produced by
cooking: in particular, after prolonged use, you are recommended to open a
window or to increase the speed of any fans.
74

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents